Demonstrates a new analytical model for coherent diffractive imaging, suggesting improved accuracy in measurements.
A linear model for coherent diffractive imaging (CDI) is proposed herein. In this model, CDI is expressed as a system of linear equations in the frequency domain of an object and illumination. The linear system can be directly determined to provide a unique solution for complex samples. The method is analytical and straightforward and does not require any approximation. The simulation results demonstrate that the proposed method is valid for all CDI-related imaging methods, such as traditional CDI, ptychography, coherent modulation imaging, and multiple-plane phase retrieval. The relationship between the method and the convergence of iterative phase retrieval is discussed. This mathematical model provides a direct method for analyzing the underlying physics of CDI and can be used to predict the accuracy and error in CDI applications, such as measurement and metrology.
No takes yet. Share an insight, caveat, or question.
He et al. (2022) studied this question.