Key result
Wearable HRV monitoring with frequency-domain filtering detects major depression with ~0.93 AUC.
Why the study?
Wearable-derived heart rate variability measurements are susceptible to motion artifacts, prompting the need for a method using signal quality indices to improve major depressive disorder screening accuracy.
Does the addition of signal quality indices in the frequency domain (SQI-FD) improve the diagnostic accuracy of a wearable HRV monitor for screening major depressive disorder?
Case-Control (n=69)
Yes
Does the addition of signal quality indices in the frequency domain (SQI-FD) improve the diagnostic accuracy of a wearable HRV monitor for screening major depressive disorder?
Effect estimate: AUC 0.93 (95% CI 0.86-0.99)
Absolute Event Rate: 0.93% vs 0.81%
The use of signal quality indices to filter wearable HRV data significantly improves the sensitivity and specificity of screening for major depressive disorder.
May support accurate wearable MDD screening; extends HRV methods but leaves open prospective validation.
To encourage potential major depressive disorder (MDD) patients to attend diagnostic sessions, we developed a novel MDD screening system based on sleep-induced autonomic nervous responses. The proposed method only requires a wristwatch device to be worn for 24 h. We evaluated heart rate variability (HRV) via wrist photoplethysmography (PPG). However, previous studies have indicated that HRV measurements obtained using wearable devices are susceptible to motion artifacts. We propose a novel method to improve screening accuracy by removing unreliable HRV data (identified on the basis of signal quality indices (SQIs) obtained by PPG sensors). The proposed algorithm enables real-time calculation of signal quality indices in the frequency domain (SQI-FD). A clinical study conducted at Maynds Tower Mental Clinic enrolled 40 MDD patients (mean age, 37.5 ± 8.8 years) diagnosed on the basis of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, and 29 healthy volunteers (mean age, 31.9 ± 13.0 years). Acceleration data were used to identify sleep states, and a linear classification model was trained and tested using HRV and pulse rate data. Ten-fold cross-validation showed a sensitivity of 87.3% (80.3% without SQI-FD data) and specificity of 84.0% (73.3% without SQI-FD data). Thus, SQI-FD drastically improved sensitivity and specificity.
No takes yet. Share an insight, caveat, or question.
Sato et al. (2023) conducted a case-control in Major Depressive Disorder (n=69). Wearable ultra-short-term HRV monitor with signal quality indices (SQI-FD) vs. Without SQI-FD thresholding was evaluated on Diagnostic accuracy (AUC) for Major Depressive Disorder (AUC 0.93, 95% CI 0.86-0.99). Screening for major depressive disorder using a wearable HRV monitor with frequency-domain signal quality indices achieved a sensitivity of 87.3%, specificity of 84.0%, and an AUC of 0.93.