Why the study?
Does the inferior shift of the P wave axis predict anterior line bidirectional block and long-term clinical outcomes after catheter ablation for longstanding persistent atrial fibrillation?
Does the inferior shift of the P wave axis predict anterior line bidirectional block and long-term clinical outcomes after catheter ablation for longstanding persistent atrial fibrillation?
An inferior shift of the P wave axis after catheter ablation for longstanding persistent AF indicates achievement and maintenance of anterior line bidirectional block, predicting better long-term clinical outcomes.
Answers are grounded in this paper and cite their sources.
P wave axis shift may aid risk stratification for very late AF recurrence after ablation; leaves open prospective validation for guiding anterior line strategy.
Background and Objectives Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods We studied 304 L-PeAF patients (77% male, 60±10yrs), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (Ã=10.4, 95% confidence interval [CI] 2.79â17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97â0.99, p=0.001), during 45.6±16.7 months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: