Key result
A novel two-stage arrhythmia identification method using U-net and RR-intervals achieved F1 scores of 98.26, 68.61, 95.99, and 47.75 for N, SVEB, VEB, and F classes on the MIT-BIH database.
Why the study?
U-net-based arrhythmia identification cannot use RR-intervals directly because heartbeat numbers and locations in the input are unfixed.
Does a novel U-net based method using RR-intervals accurately identify multiple arrhythmias in ECG signals?
Does a novel U-net based method using RR-intervals accurately identify multiple arrhythmias in ECG signals?
The proposed convolutional neural network method effectively utilizes RR intervals to identify multiple types of arrhythmias with high accuracy for non-ectopic and ventricular ectopic beats.
May aid automated ECG arrhythmia detection; leaves open prospective clinical validation before adoption.
Objective . The arrhythmia identification method based on the U-net has the potential for fast application. The RR-intervals have been proven to improve the performance of single-heartbeat identification methods. However, because both the heartbeats number and location in the input of the U-net are unfixed, the approach based on the U-net cannot use RR-intervals directly. To solve this problem, we proposed a novel method. The proposed method also can identify heartbeats of four classes, including non-ectopic (N), supraventricular ectopic beat (SVEB), ventricular ectopic beat (VEB), and fusion beat (F). Approach . Our method consists of the pre-processing and the two-stage identification framework. In the pre-processing part, we filtered input signals with a band-pass filter and created the auxiliary waveforms by RR-intervals. In the first stage of the framework, we designed a network to handle input signals and auxiliary waveforms. We proposed a masking operation to separate the input signal into two signals according to the result of the network. The first signal contains heartbeats of SVEB and VEB. The second signal includes heartbeats of N and F. The second stage consists of two networks and can further identify the heartbeats of SVEB, VEB, N, and F from these two signals. Main result . We validated our method on the MIT-BIH arrhythmia database with the inter-patient model. For classes N, SVEB, VEB, and F, our approach achieved F1 scores of 98.26, 68.61, 95.99, and 47.75, respectively. Significance . Our method not only can effectively utilize RR intervals but also can identify multiple arrhythmias.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2022) studied Arrhythmia. Arrhythmia identification method based on U-net and RR-intervals was evaluated on F1 scores for identifying non-ectopic (N), supraventricular ectopic beat (SVEB), ventricular ectopic beat (VEB), and fusion beat (F). A novel two-stage arrhythmia identification method using U-net and RR-intervals achieved F1 scores of 98.26, 68.61, 95.99, and 47.75 for N, SVEB, VEB, and F classes on the MIT-BIH database.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: