Exploring automated plasma phospho-tau217 assays for the diagnosis of Down syndrome-related Alzheimer’s disease

ZSZinayida SchlachetzkiOLOliver LangfordMZMatthew Zammit

Key Points

  • This study aims to assess the accuracy of automated plasma phospho-tau217 assays for diagnosing Alzheimer’s disease in individuals with Down syndrome.
  • Exploratory study with participants from the NIH Trial Ready Cohort - Down syndrome (n = 39)
  • Analyzed plasma phospho-tau217 using two automated assays: C2N Diagnostics' PrecivityAD2 and Fujirebio's Lumipulse
  • Primary outcome assessed was β-amyloid AD pathology via amyloid PET scanning.
  • Lumipulse assay achieved an AUC of 0.94 (95% CI 0.84, 1.00) with sensitivity of 0.88 and specificity of 0.90.
  • C2N assay achieved an AUC of 0.91 (95% CI 0.77, 1.00) with specificity of 0.94 and an overall accuracy of 0.92 (95% CI 0.82-1.00).
  • Both assays demonstrated strong potential for routine Alzheimer’s disease screening in Down syndrome populations.

Abstract

BACKGROUND: Individuals with Down syndrome (DS) develop a genetic form of Alzheimer's disease (AD) due to an extra copy of chromosome 21, which contains the APP gene. Blood-based biomarkers of AD are becoming increasingly adopted in research and clinical practice. These tests hold promise for diagnosing AD in DS once validated. METHODS: In this exploratory study, we assessed plasma phospho-tau217 (p-tau217) in participants (n = 39) from the NIH Trial Ready Cohort - Down syndrome (TRC-DS), using predefined amyloid-PET cutoffs. Plasma p-tau217 was measured via two fully automated assays: C2N Diagnostics' PrecivityAD2 mass spectrometry and Fujirebio's Lumipulse immunoassay. The primary outcome was β-amyloid AD pathology, defined by amyloid PET > 18 centiloids. RESULTS: Both p-tau217 assays showed high accuracy: AUCs of 0.94 (95% CI 0.84, 1.00) for Lumipulse and 0.91 (95% CI 0.77, 1.00) for C2N, with sensitivities of 0.88 (95% CI 0.62, 1.00), specificities of 0.90 (95% CI 0.77, 1.00) and 0.94 (95% CI 0.84, 1.00), and overall accuracies of 0.90 (95% CI 0.79, 0.97) and 0.92 (95% CI 0.82-1.00), respectively, when using maximized Youden index cutpoints. CONCLUSION: These preliminary results are comparable to composite plasma measures. In summary, automated p-tau217 tests offer strong potential for routine AD screening in individuals with DS.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Schlachetzki et al. (2026) studied this question.

synapsesocial.com/papers/6a22672f763171746d545e6ehttps://doi.org/10.1038/s43856-026-01709-0
Ask AI
Helpful
Bookmark
Share
View Full Paper