PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 5, 2026Forensic Science International0 citationsOpen Access

Persistence of organic and inorganic gunshot residues on hands, forearms, and face of shooters 24hours after a high number of discharges

View Full Paper
VMVirginie Redouté MinzièreTTThomas TilborgAGAnne‐Laure Gassner

Key Points

  • This study aims to understand how long organic and inorganic gunshot residues remain detectable on shooters after multiple discharges.
  • Gunshot residues were collected using carbon stubs from shooters with high and low exposure to firearms.
  • Organic compounds were analyzed using ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS).
  • Inorganic residues were detected using scanning electron microscopy coupled with energy-dispersive X-ray spectrometry (SEM/EDS).
  • Both organic and inorganic gunshot residues were detectable 24 hours after 23 to 100 firearm discharges.
  • Higher discharge numbers (up to 100) resulted in increased residue detection, while fewer discharges (30-50) led to lower amounts found.
  • Significant amounts of organic gunshot residues were identified even when using heavy-metal free ammunition, with no lead particles found.

Abstract

Understanding the persistence of both organic and inorganic gunshot residues (OGSR and IGSR) is essential for the accurate interpretation of specimens collected hours after firearm discharges. This study investigates the persistence of OGSR and IGSR on the shooter’s hands, forearms, face and on work desk, 24 hours after a high number of discharges. GSR were collected using carbon stubs on three individuals with high GSR prevalence risk (frequent firearm users) and two individuals with infrequent exposure to firearms. Organic compounds were first extracted and then analysed using ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Subsequently, IGSR particles were detected on the same stub using scanning electron microscopy coupled with energy-dispersive X-ray spectrometry (SEM/EDS). The results of this study highlighted that both types of GSR could still be detected 24 hours after 23 to 100 discharges, despite activities such as showering, changing clothes, sleeping and working. Higher numbers of discharges (i.e. 100) produced more GSR, while fewer discharges (i.e., 30-50) generally resulted in lower amounts of residue being detected. The experiment with heavy-metal free ammunition resulted in significant amounts of OGSR and no PbSbBa particles, showing the added value of OGSR analysis for such munition types. GSR could also be detected in the offices of the shooters on objects such as their desk, mouse or keyboard. The results of this study should be considered when persons of interest have discharged a firearm several times in the 24 hours before collection occurs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Minzière et al. (2026) studied this question.

synapsesocial.com/papers/6a22672f763171746d545f7ahttps://doi.org/10.1016/j.forsciint.2026.113032
Ask AI
Helpful
Bookmark
Share
View Full Paper