Key result
An energy-efficient recurrent convolutional neural network architecture achieved greater than 94% accuracy for atrial fibrillation detection while requiring only 114 trainable parameters.
Why the study?
There is an increasing demand for deep learning models designed for physical implementation on small portable devices with limited energy supply for AFib detection.
An energy-efficient RCNN with only 114 parameters can effectively detect AFib, enabling implementation on small portable devices like smartwatches.
May enable on-device AF detection in wearables; leaves open prospective clinical validation before adoption.
Electrocardiograms (ECG) record the heart activity and are the most common and reliable method to detect cardiac arrhythmias, such as atrial fibrillation (AFib). Lately, many commercially available devices such as smartwatches are offering ECG monitoring. Therefore, there is increasing demand for designing deep learning models with the perspective to be physically implemented on these small portable devices with limited energy supply. In this paper, a workflow for the design of small, energy-efficient recurrent convolutional neural network (RCNN) architecture for AFib detection is proposed. However, the approach can be well generalized to every type of long time series. In contrast to previous studies, that demand thousands of additional network neurons and millions of extra model parameters, the logical steps for the generation of a CNN with only 114 trainable parameters are described. The model consists of a small segmented CNN in combination with an optimal energy classifier. The architectural decisions are made by using the energy consumption as a metric in an equally important way as the accuracy. The optimisation steps are focused on the software which can be embedded afterwards on a physical chip. Finally, a comparison with some previous relevant studies suggests that the widely used huge CNNs for similar tasks are mostly redundant and unessentially computationally expensive.
No takes yet. Share an insight, caveat, or question.
Katsaouni et al. (2021) studied Atrial Fibrillation (AFib) (n=16,000). Energy-efficient recurrent convolutional neural network (RCNN) vs. Standard large Convolutional Neural Networks was evaluated on Atrial fibrillation detection accuracy and model complexity (number of parameters). An energy-efficient recurrent convolutional neural network architecture achieved greater than 94% accuracy for atrial fibrillation detection while requiring only 114 trainable parameters.