Demonstrates energy optimisation in office buildings, suggesting scalable facade management solutions.
Adaptive facade systems play a crucial role in improving energy efficiency and visual comfort in office buildings, yet their operation often depends on sensor-based feedback or rule-driven logic that limits scalability and robustness. This study introduces a sensor-free machine learning framework for optimising venetian blind slat angles using only weather and temporal parameters. A south-facing single-zone office in Munich, Germany was modelled using Honeybee/EnergyPlus to generate a simulation-based dataset of hourly energy performance under varying slat-angle configurations. Two supervised learning models, Random Forest and XGBoost, were trained to solve a multi-class classification problem in which each hourly sample was assigned one of 18 discrete blind-slat angle classes (0°-170° in 10° increments), representing the energy-optimal configuration. Among the tested models, XGBoost achieved the highest predictive performance with 88% accuracy and a circular mean absolute error of 3.61°. When implemented for adaptive control, the proposed strategy reduced total summer energy consumption by 21.4% compared to the best-performing fixed-angle configuration. The results demonstrate that simulation-based, data-driven shading control can effectively replace sensor-dependent systems, offering a scalable, low-cost solution for intelligent facade management and energy optimisation in modern office buildings.
No takes yet. Share an insight, caveat, or question.
Hoseini et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: