Key points are not available for this paper at this time.
We report a piezoelectrically driven and hydraulically amplified axial polymer microvalve. The microvalve is normally open and is assembled primarily with stereolithographically fabricated polymer components. An incompressible elastomer is used as a solid hydraulic medium to convert the small axial displacement of a piezoelectric actuator into a large valve head stroke while maintaining a large blocking force. Also, the axial design of the microvalve enables densely packed valve arrays. One application of this microvalve is in pneumatic tactile displays, which operates against gas pressure up to approximately 90 kPa and switching speed between 1 and 200 Hz. The current valve design has a maximum static hydraulic amplification ratio of 5 at 30 V driving voltage and a maximum valve head stroke of 37 µm at 150 V. Under a 94.4 kPa differential pressure, the flow rate of the valve and the closing voltage measure are 785 mL min−1 and 150 V, respectively. The function of the microvalve as an on–off switch for a pneumatic microbubble tactile actuator is demonstrated.
Wu et al. (Wed,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: