Answers are grounded in this paper and cite their sources.
This article presents data evaluating an air dispersion model, INPUFF-2, in predicting downwind odors fromanimal production facilities. According to the Wilcoxon Signed Rank Test, the model is able to predict the downwind odorlevels at distances of 100, 200, and 300 m from odor sources with confidence of 95%, 92%, and 81%, respectively. Atfarther distances, such as 400 and 500 m, the accuracy of prediction by the model is significantly reduced. This reductioncould be due to the reduction in the nasal sensitivity of human sniffers for low levels of odors at such distances, whichincreases the errors in differentiation. Further research on methods of evaluating air dispersion models for a long rangeis needed to determine the performance of models. In addition, it was found that INPUFF-2 model can predict downwindodor concentrations as measured in units of odor threshold from either a single or multiple sources with confidenceranging from 81 to 90% based on the Wilcoxon Signed Rank Test.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2000) studied this question.