Why the study?
A simple, accurate, and noninvasive method for rat aortic pulse wave velocity measurement was lacking, particularly for accurately measuring transit distance.
Does a new equation-based Doppler ultrasound method improve the accuracy of aortic pulse wave velocity measurement compared to the traditional body surface method in rats?
Does a new equation-based Doppler ultrasound method improve the accuracy of aortic pulse wave velocity measurement compared to the traditional body surface method in rats?
A novel equation-based Doppler ultrasound method provides a more accurate and reliable noninvasive assessment of aortic pulse wave velocity in rat models compared to traditional surface measurements.
May refine noninvasive aortic PWV assessment in rat models; leaves open translation and validation in humans.
There is still lack of a simple, accurate, and noninvasive method for rat aortic pulse wave velocity (PWV) measurement, especially the transit distance cannot be accurately measured. Thus, we aimed to derive an equation for aortic transit distance as a function of the nose-to-rump length ( L) and to test the hypothesis that aortic PWV measured by new equation combined with Doppler ultrasound (the “equation method”) may have stronger correlation with invasive measurements than traditional “body surface method.” Two-hundred male Sprague-Dawley (SD) rats (age ranged 5–24 wk) were included in protocol 1, and the aortic transit distances were measured postmortem. In protocol 2, heart-femoral PWV and carotid-femoral PWV were measured by equation method (hfPWV E , cfPWV E ) and also by traditional body surface method (hfPWV S , cfPWV S ) in another 30 young and 28 old rats. These measurements were then validated against invasively measured hfPWV I and cfPWV I from the same animal. Protocol 1 showed that the heart-femoral transit distance could be calculated by 0.6086 × L − 1.6523, and the carotid-femoral transit distance by 0.4614 × L + 1.8335. In protocol 2, in young rats, the Pearson r between hfPWV E , cfPWV E , hfPWV S , and cfPWV S and their corresponding invasive measurement were 0.8962, 0.8509, 0.8387, and 0.7828, respectively (all P < 0.0001). In the old group, the results were 0.8718, 0.7999, 0.8330, and 0.7112, respectively (all P < 0.0001). The hfPWV E and cfPWV E showed better agreement with hfPWV I and cfPWV I and lower intra- and interobserver variability compared with hfPWV S and cfPWV S in both groups. These findings demonstrate that this novel methodology provides a simple and reliable method for rat noninvasive aortic PWV measurement. NEW & NOTEWORTHY First, when measuring aortic PWV in SD rat models, the heart-femoral transit distance can be estimated by 0.6086 × L − 1.6523, and the carotid-femoral distance transit distance can be estimated by 0.4614 × L + 1.8335, where L (in mm) is nose-to-rump length. Second, this novel methodology for aortic PWV measurement was validated with a closer correlation with the invasive measurements than traditional approach in young and old rats. Third, this study provides a simple and reliable method for rat noninvasive aortic PWV measurement.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: