Key result
A patch-clamp method using membrane potential ramps generated a reproducible signature current in isolated cardiac myocytes, allowing simultaneous assay of ion-channel blockers.
Why the study?
Does the use of membrane potential ramps allow for the rapid determination of ion-channel selectivity of drugs in isolated cardiac myocytes?
Does the use of membrane potential ramps allow for the rapid determination of ion-channel selectivity of drugs in isolated cardiac myocytes?
A novel patch-clamp method using membrane potential ramps provides a rapid and consistent way to evaluate the ion-channel selectivity of antiarrhythmic compounds in isolated cardiac myocytes.
May accelerate preclinical antiarrhythmic screening; leaves open validation in human myocytes and clinical translation.
BACKGROUND: We describe a simple method using membrane potential ramps for rapidly determining the ion-channel selectivity of drugs that affect action-potential duration in isolated cardiac myocytes. The method allows the simultaneous assay of compounds on a number of ionic currents in a single cardiac cell. METHODS: Trains of membrane potential ramps were applied from -90 to +70 mV at 0.33 Hz to obtain a consistent "signature current," in which the major individual currents involved in the cardiac action potential could be easily identified. Confirmatory experiments were performed using known inhibitors of these currents. RESULTS: The identities of the currents in the signature were established by varying the concentrations of extracellular cations and by adding known ion channel blockers to superfusion solutions. Inhibition of each current had a characteristic and reproducible effect on the overall signature current. CONCLUSIONS: The consistent current signature in the presence and absence of blockers suggests that this method could be used for tertiary electrophysiological evaluation of compounds, eg, in a drug discovery program focusing on antiarrhythmic agents. The ability to assay for secondary effects of novel compounds against multiple currents in the target cell type is convenient and avoids the artefacts associated with using artificial expression systems.
No takes yet. Share an insight, caveat, or question.
Spencer et al. (2000) studied Cardiac electrophysiology. Membrane potential ramps (patch-clamp method) was evaluated on Ion-channel selectivity determination via signature current. A patch-clamp method using membrane potential ramps generated a reproducible signature current in isolated cardiac myocytes, allowing simultaneous assay of ion-channel blockers.