Key result
True bipolar left ventricular pacing did not significantly differ from extended bipole pacing in total electrical activation times (74.7 vs 72.4; P=0.45).
Why the study?
Does true bipolar pacing improve electrical activation times compared to extended bipole pacing in patients undergoing CRT?
Does true bipolar pacing improve electrical activation times compared to extended bipole pacing in patients undergoing CRT?
True bipolar pacing does not significantly improve electrical activation times compared to extended bipolar pacing, suggesting other mechanisms explain its associated mortality benefits.
Answers are grounded in this paper and cite their sources.
True bipolar LV pacing yields no activation time benefit versus extended bipole in CRT; leaves open other mechanisms and needs randomized validation.
BACKGROUND: Cardiac resynchronization therapy (CRT) is typically delivered via quadripolar leads that allow stimulation using either true bipolar pacing, where stimulation occurs between two electrodes (BP) on the quadripolar lead, or extended bipole (EBP) left ventricular (LV) pacing, with the quadripolar electrodes and right ventricular coil acting as the cathode and anode, respectively. True bipolar pacing is associated with reductions in mortality and it has been postulated that these differences are the result of enhanced electrical activation. MATERIALS AND METHODS: Patients undergoing a CRT underwent an electrocardiographic imaging study where electrical activation data were recorded while different LV pacing vectors were temporarily programmed. RESULTS: There were no differences in the total electrical activation times or dispersion of electrical activation between biventricular pacing with bipolar or corresponding EBP LV vector configurations (left ventricular total activation time [LVtat] BP 74.70 ± 18.07 vs EBP 72.4 ± 22.64; P = 0.45). When dichotomized according to etiology, no difference was observed in the activation time with either BP or EBP pacing (LVtat BP ischemic cardiomyopathy 72.2 ± 17.4 vs BP dilated cardiomyopathy 79.9 ± 18.9; P = 0.38). CONCLUSIONS: Bipolar pacing alters the mechanical activation sequence of the LV and is associated with reductions in all-cause mortality. It has been postulated these benefits derive from improvements in electromechanical activation of the LV. Our study would suggest that true bipolar pacing does not necessarily result in more favorable activation of the LV or improved electrical resynchronization and other mechanisms should be explored.
No takes yet. Share an insight, caveat, or question.
Sieniewicz et al. (2018) studied Patients undergoing cardiac resynchronization therapy. True bipolar left ventricular pacing vs. Extended bipole left ventricular pacing was evaluated on Left ventricular total activation time (p=0.45). True bipolar left ventricular pacing did not significantly differ from extended bipole pacing in total electrical activation times (74.7 vs 72.4; P=0.45).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: