Key result
Frequency domain analysis demonstrated low correlation (ICC = 0.234) with time complex analysis when calculating atrial fibrillation activation rates.
Why the study?
Does domain frequency analysis correlate with time complex analysis when calculating activation rates in atrial fibrillation patients?
Observational
Does domain frequency analysis correlate with time complex analysis when calculating activation rates in atrial fibrillation patients?
There is low correlation between frequency domain and time complex methods for analyzing AF activation rates, highlighting clinical limitations in these measurements.
AF activation rate methods require caution against interchangeable use; leaves open standardization needs for future research.
BACKGROUND: Atrial fibrillation (AF) activation rates have been calculated using both frequency domain and time complex analyses. Direct comparisons of these methods are limited. We report: (1) their correlation when measuring AF activation rates, (2) comparisons of recording durations required to minimize variability, and (3) differences in the temporal reproducibility. METHODS: AF activation rates were calculated using domain frequency (DF) (via fast Fourier transform) and time complex (TC) (via beat-to-beat activation measurements) analyses. We compared: (1) AF frequencies derived from each method; (2) successively longer subinterval durations to their 16-second reference intervals, and (3) the correlation between consecutively collected 8-second segments and segments collected 10 minutes apart. RESULTS: There was low intraclass correlation coefficient (ICC = 0.234) when comparing AF activation rates derived using DF versus TC analysis. There was no difference in the frequencies between any of the subintervals compared to their 16-second reference intervals, but variability of measurements was higher for intervals <8 seconds (P < 0.01). Correlations between successive segments and segments taken 10 minutes apart were 0.92 and 0.75 using DF analysis (P < 0.001), and 0.72 and 0.49 using TC analysis (P < 0.001). CONCLUSIONS: There is low correlation between the DF and TC methods of analyzing AF activation rates. While AF rates do not differ between subintervals and 16-second reference electrograms, the variability of measurements is dependent upon the subinterval duration, and increases for durations less than 8 seconds. AF rates were prone to change over a 10-minute time period. These results point out existing clinical limitations of measuring atrial activation rates in AF patients.
No takes yet. Share an insight, caveat, or question.
Biviano et al. (2011) conducted an observational in Atrial fibrillation. Frequency domain (DF) analysis vs. Time complex (TC) analysis was evaluated on Correlation of atrial fibrillation activation rates (ICC 0.234). Frequency domain analysis demonstrated low correlation (ICC = 0.234) with time complex analysis when calculating atrial fibrillation activation rates.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: