A non-contact drowsiness detection system combining LF/HF ratio from HRV and PERCLOS achieved a sensitivity of 88.9%, specificity of 93.5%, and overall accuracy of 92.5%.
A non-contact drowsiness detection system combining facial HRV and eyelid closure metrics demonstrated high accuracy for detecting driver fatigue.
Accidents caused by fatigue occur frequently, and numerous scholars have devoted tremendous efforts to investigate methods to reduce accidents caused by fatigued driving. Accordingly, the assessment of the spirit status of the driver through the eyes blinking frequency and the measurement of physiological signals have emerged as effective methods. In this study, a drowsiness detection system is proposed to combine the detection of LF/HF ratio from heart rate variability (HRV) of photoplethysmographic imaging (PPGI) and percentage of eyelid closure over the pupil over time (PERCLOS), and to utilize the advantages of both methods to improve the accuracy and robustness of drowsiness detection. The proposed algorithm performs three functions, including LF/HF ratio from HRV status judgment, eye state detection, and drowsiness judgment. In addition, this study utilized a near-infrared webcam to obtain a facial image to achieve non-contact measurement, alleviate the inconvenience of using a contact wearable device, and for use in a dark environment. Furthermore, we selected the appropriate RGB channel under different light sources to obtain LF/HF ratio from HRV of PPGI. The main drowsiness judgment basis of the proposed drowsiness detection system is the use of algorithm to obtain sympathetic/parasympathetic nervous balance index and percentage of eyelid closure. In the experiment, there are 10 awake samples and 30 sleepy samples. The sensitivity is 88.9%, the specificity is 93.5%, the positive predictive value is 80%, and the system accuracy is 92.5%. In addition, an electroencephalography signal was used as a contrast to validate the reliability of the proposed method.
Chang et al. (Tue,) conducted a other in Drowsiness (n=40). Drowsiness detection system combining LF/HF ratio from HRV of PPGI and PERCLOS vs. Electroencephalography signal was evaluated on System accuracy. A non-contact drowsiness detection system combining LF/HF ratio from HRV and PERCLOS achieved a sensitivity of 88.9%, specificity of 93.5%, and overall accuracy of 92.5%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: