Key result
Micra implantation via the right internal jugular vein achieves 100% success without acute complications.
Why the study?
Leadless pacemaker implantation via the right internal jugular vein is an emerging alternative to traditional femoral access, but its electrical performance, procedural efficiency, and safety needed evaluation.
Does Micra transcatheter pacing system implantation via the right internal jugular vein provide safe and effective electrical performance in patients requiring pacing?
Observational (n=35)
Yes
Does Micra transcatheter pacing system implantation via the right internal jugular vein provide safe and effective electrical performance in patients requiring pacing?
Micra leadless pacemaker implantation via the right internal jugular vein is a highly effective and safe alternative to the traditional femoral approach.
No takes yet. Share an insight, caveat, or question.
RIJV approach may be feasible for Micra implantation; leaves open need for comparative trials before clinical adoption.
BACKGROUND: Leadless pacemaker implantation via the right internal jugular vein (RIJV) is an emerging alternative to the traditional femoral approach, offering favorable anatomical access and potential procedural advantages. AIMS: Our aim was to assess electrical performance, procedural efficiency and safety of Micra leadless pacemaker implantation via RIJV. METHODS: Thirty-five consecutive patients who underwent Micra transcatheter pacing system (TPS) implantation via RIJV at 7 clinical centers in Poland between November 2024 and November 2025 were included in this registry. Procedural safety and efficacy were assessed, and in-hospital as well as short-term follow-up electrical parameters were analyzed. RESULTS: Implantation success was achieved in 100% of cases. There were no significant changes in R-wave sensing (8.41 [2.45] vs. 9.20 [3.43] vs. 9.34 [3.60] mV; P = 0.45) or pacing threshold (0.5 [0.38-0.57] vs. 0.5 [0.38-0.63] vs. 0.5 [0.38-0.69] V; P = 0.25) between procedure, predischarge, and 1-3-month follow-up. Impedance showed a decrease tendency across all time points (680 [620-745] vs. 630 [590-690] vs. 570 [535-607.5] Ω; P = 0.06). No mild or severe acute or in-hospital complications related to the procedure were observed. CONCLUSIONS: Micra TPS implantation via the RIJV is a highly effective and safe alternative to femoral access when performed in experienced cardiology centers.
Michalak et al. (2026) conducted an observational in Patients requiring leadless pacemaker (n=35). Micra transcatheter pacing system implantation via the right internal jugular vein was evaluated on Implantation success. Micra transcatheter pacing system implantation via the right internal jugular vein achieved a 100% implantation success rate with no acute or in-hospital complications.