PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 2002IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control405 citations

Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography

View Full Paper
MTMickaël TanterJBJérémy BercoffLSLaurent Sandrin

Key Points

Key points are not available for this paper at this time.

Abstract

This paper describes a new technique for two-dimensional (2-D) imaging of the motion vector at a very high frame rate with ultrasound. Its potential is experimentally demonstrated for transient elastography. But, beyond this application, it also could be promising for color flow and reflectivity imaging. To date, only axial displacements induced in human tissues by low-frequency vibrators were measured during transient elastography. The proposed technique allows us to follow both axial and lateral displacements during the shear wave propagation and thus should improve Young's modulus image reconstruction. The process is a combination of several ideas well-known in ultrasonic imaging: ultra-fast imaging, multisynthetic aperture beamforming, 1-D speckle tracking, and compound imaging. Classical beamforming in the transmit mode is replaced here by a single plane wave insonification increasing the frame rate by at least a factor of 128. The beamforming is achieved only in the receive mode on two independent subapertures. Comparison of successive frames by a classical 1-D speckle tracking algorithm allows estimation of displacements along two different directions linked to the subapertures beams. The variance of the estimates is finally improved by tilting the emitting plane wave at each insonification, thus allowing reception of successive decorrelated speckle patterns.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tanter et al. (2002) studied this question.

synapsesocial.com/papers/6a328d28c93616f7345855d9https://doi.org/10.1109/tuffc.2002.1041078
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Shear elasticity probe for soft tissues with 1-D transient elastography2002 · 420 citations
  2. 2Multiple crossed-beam ultrasound Doppler velocimetry1978 · 170 citations
  3. 3Adaptive focusing in scattering media through sound-speed inhomogeneities: The van Cittert Zernike approach and focusing criterion1994 · 261 citations
  4. 4Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis1987 · 172 citations
  5. 5Multi-Angle Compound Imaging1998 · 206 citations