January 1, 2004Emergency Medicine Journal281 citationsOpen Access

Role of "Ischemia Modified Albumin", a new biochemical marker of myocardial ischaemia, in the early diagnosis of acute coronary syndromes

MSMukesh Kumar Sinha

Key Result

Ischemia Modified Albumin (IMA) demonstrated 82% sensitivity for detecting an ischaemic origin of acute chest pain at presentation, compared to 45% for ECG and 20% for cardiac troponin T.

Study Design

Type

Observational (n=208)

Structured PICO

Does Ischemia Modified Albumin (IMA) testing improve the early diagnosis of acute coronary syndromes in patients presenting to the emergency department within three hours of acute chest pain?

P
Population
208 patients presenting to the emergency department within three hours of acute chest pain.
E
Exposure
Ischemia Modified Albumin (IMA) measurement at presentation
C
Comparator
12-lead ECG and cardiac troponin T (cTnT)
O
Outcome
Sensitivity for an ischaemic origin of chest pain (final diagnoses of unstable angina, ST segment elevation, and non-ST segment elevation myocardial infarction)surrogate

Ischemia Modified Albumin (IMA) is a highly sensitive early biomarker for diagnosing myocardial ischemia in patients presenting with acute chest pain, especially when combined with ECG and troponin.

Abstract

BACKGROUND: Diagnosis of cardiac ischaemia in patients attending emergency departments (ED) with symptoms of acute coronary syndromes is often difficult. Cardiac troponin (cTn) is sensitive and specific for the detection of myocardial damage but may not rise during reversible myocardial ischaemia. Ischemia Modified Albumin (IMA) has recently been shown to be a sensitive and early biochemical marker of ischaemia. METHODS AND RESULTS: This study evaluated IMA in conjunction with ECG and cTn in 208 patients presenting to the ED within three hours of acute chest pain. At presentation, a 12-lead ECG was recorded and blood taken for IMA and cardiac troponin T (cTnT). Patients underwent standardised triage, diagnostic procedures, and treatment. Results of IMA, ECG, and cTnT, alone and in combination, were correlated with final diagnoses of non-ischaemic chest pain, unstable angina, ST segment elevation, and non-ST segment elevation myocardial infarction. In the whole patient group, sensitivity of IMA at presentation for an ischaemic origin of chest pain was 82%, compared with 45% of ECG and 20% of cTnT. IMA used together with cTnT or ECG, had a sensitivity of 90% and 92%, respectively. All three tests combined identified 95% of patients whose chest pain was attributable to ischaemic heart disease. In patients with unstable angina, sensitivity of IMA used alone was equivalent to that of IMA and ECG combined. CONCLUSIONS: IMA is highly sensitive for the diagnosis of myocardial ischaemia in patients presenting with symptoms of acute chest pain.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Mukesh Kumar Sinha (2004) conducted an observational in Acute chest pain / Acute coronary syndromes (n=208). Ischemia Modified Albumin (IMA) vs. ECG and cardiac troponin T (cTnT) was evaluated on Sensitivity for an ischaemic origin of chest pain at presentation. Ischemia Modified Albumin (IMA) demonstrated 82% sensitivity for detecting an ischaemic origin of acute chest pain at presentation, compared to 45% for ECG and 20% for cardiac troponin T.

synapsesocial.com/papers/6a3302a67282da616280750dhttps://doi.org/10.1136/emj.2003.006007