Study estimates state of charge in lead acid batteries, suggesting improved battery management practices.
Estimation of State of Charge (SOC) of batteries plays a vital role in Battery Management Systems(BMS). It is important to enhance the lifetime of a battery and give the user an accurate estimation of available runtime. This study aims to estimate the battery SOC based on current through and voltage across a battery using Support Vector Regression (SVR). Tests are run on SIMULINK using a 6 V, 4.5 Ah Lead Acid battery. Hyper parameters that decide the accuracy of SVR are estimated using Grid Search and Particle Swarm Optimization (PSO). The SVR maintains a high level of accuracy, with a Mean Squared Error (MSE) of 0.45% for PSO and 0.95% for GS.
No takes yet. Share an insight, caveat, or question.
Surendar et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: