Answers are grounded in this paper and cite their sources.
Evaluates the effects of ions on etch selectivity in Si0.7Ge0.3, suggesting ion screening improves outcomes.
Selective etching of Si 0.7 Ge 0.3 was investigated in CF 4 inductively coupled plasma using an ion‐screening approach to decouple ion and radical contributions. Without ion screening, fluorocarbon polymer accumulation reduced etch selectivity, whereas ion screening suppressed polymer deposition and produced smoother surfaces with higher selectivity. Plasma simulations revealed that polymer deposition is governed by the balance between polymer‐forming radicals (CF 2 ·, CF·) and polymer‐etching radicals (F·). Ion screening reduced CF x + ion fluxes by 60%–85% while leaving radical fluxes nearly unchanged. Pressure‐, power‐, and geometry‐dependent etch‐rate and selectivity trends were analyzed using simulated F· radical and F + ion fluxes. Under optimized ion‐screened conditions, polymer deposition was minimized, and Si 0.7 Ge 0.3 /Si selectivity reached 30:1 in multilayer stacks.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: