Key result
AI-assisted stress echocardiography yields similar QALYs to standard care but proves cost-effective.
Why the study?
The economic impact of AI-assisted stress echocardiography in the NHS diagnostic pathway for CAD had not been established.
Does AI-assisted stress echocardiography improve cost-effectiveness and quality-adjusted life-years in patients with suspected CAD compared to standard care?
RCT (n=2,213)
randomized
Yes
Does AI-assisted stress echocardiography improve cost-effectiveness and quality-adjusted life-years in patients with suspected CAD compared to standard care?
AI-assisted stress echocardiography is a potentially cost-effective diagnostic strategy for suspected CAD, provided AI costs remain below £35.35 per case or £45.93 with clinician time savings.
May support AI-assisted stress echocardiography adoption in suspected CAD if costs remain low; extends RCT evidence on AI diagnostic cost-effectiveness.
OBJECTIVES: To assess the economic impact of Artificial Intelligence (AI)-assisted stress echocardiography (SE) in the National Health Service (NHS) diagnostic pathway for coronary artery disease (CAD) using cost-effectiveness analysis and cost-consequence analysis alongside a multicenter randomized controlled trial. METHODS: This evaluation was embedded in the PROTEUS trial, a 20-hospital NHS randomized controlled trial enrolling 2213 patients with suspected CAD undergoing SE. Patients were randomized to standard care (control) or AI-assisted SE (intervention). Outcomes were assessed using EuroQol 5-dimension 5-level (EQ-5D-5L) and Seattle Angina Questionnaire (SAQ-7), with quality-adjusted life-years (QALYs) estimated over 6 months. NHS costs were obtained from a costing study. Cost-consequence analysis compared within- and between-group outcomes. Cost-effectiveness analysis used a decision tree incorporating AI cost scenarios and clinician time savings. Probabilistic sensitivity analysis assessed uncertainty. RESULTS: Diagnostic accuracy was high in both groups (97.2% control; 96.9% intervention). SAQ-7 scores improved significantly within both groups (P < .001), with no between-group differences. EQ-5D-5L showed no significant within-group changes, except self-care (control: P = .017; intervention: P = .032), and no between-group differences. QALYs were similar (0.392 intervention vs 0.390 control; P = .818). Mean NHS costs were £376.72 (intervention) vs £366.08 (control). In the base case without AI costs, the incremental cost-effectiveness ratio was £6939 per QALY. The intervention remained cost-effective for AI costs up to £35.35 per case or £45.93 with clinician time savings. Sensitivity analyses supported the results. CONCLUSIONS: AI-assisted SE may be a cost-effective addition to NHS CAD diagnostics, with value driven by costs, accuracy, and efficiency.
No takes yet. Share an insight, caveat, or question.
Chauhan et al. (2026) conducted an RCT in suspected coronary artery disease (CAD) (n=2,213). AI-assisted stress echocardiography vs. standard care was evaluated on Quality-adjusted life-years (QALYs) over 6 months (p=.818). AI-assisted stress echocardiography yielded similar QALYs to standard care (0.392 vs 0.390; P=.818) and was cost-effective with an incremental cost-effectiveness ratio of £6939 per QALY.