Key result
Transvenous retrieval of chronic dual-chamber leadless pacemakers achieves 100% complication-free preclinical success.
Why the study?
As dual-chamber leadless pacemaker systems increase clinical adoption, device retrieval for upgrade or replacement becomes an important capability, requiring preclinical performance and safety evaluation.
Does transvenous retrieval safely and effectively remove chronically implanted dual-chamber leadless pacemakers in an ovine model?
Does transvenous retrieval safely and effectively remove chronically implanted dual-chamber leadless pacemakers in an ovine model?
Transvenous retrieval of chronically implanted dual-chamber leadless pacemakers is safe and highly successful in a preclinical ovine model at nearly 2 years post-implant.
Preclinical retrieval data support LP design feasibility; leaves open human safety and efficacy pending trials.
BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.
No takes yet. Share an insight, caveat, or question.
Banker et al. (2023) studied Healthy ovine subjects (n=9). Transvenous retrieval of dual-chamber leadless pacemakers was evaluated on Successful device retrieval without complications. Transvenous retrieval of chronically implanted dual-chamber leadless pacemakers was successful in 100% of devices (18/18) without complications at a median of 1.9 years postimplant.