Answers are grounded in this paper and cite their sources.
Demonstrates effective COD removal in industrial wastewater, indicating a strong treatment option.
The treatment of industrial wastewater containing refractory organics contributing to chemical oxygen demand (COD) remains a critical environmental challenge. Here, an integrated electrochemical oxidation‐capacitive deionization (EO‐CDI) system based on an ionization‐electrosorption mechanism is developed. In this design, the EO unit serves as a low‐energy conversion stage rather than a complete mineralization process, transforming refractory organics into ionizable intermediates that are subsequently removed by electrosorption in the CDI unit. Chromatographic analyses confirm the formation of carboxylic acid intermediates and their subsequent removal, validating the proposed ionization‐electrosorption pathway. For simulated phenol wastewater, the system achieves 80% COD removal. For chloride‐containing industrial wastewater with a complex ionic composition (∼200 mg L −1 COD, ∼10 mS cm −1 ), stable COD removal of 95% is achieved with a low specific energy consumption of 7.6 kWh m −3 . Moreover, the EO‐CDI system maintains stable performance over 50 operating cycles. These results demonstrate that the EO‐CDI hybrid system provides an energy‐efficient and robust strategy for advanced industrial wastewater treatment.
No takes yet. Share an insight, caveat, or question.
Lei et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: