Key result
Preoperative echo identifies anomalous coronary arteries in tetralogy of Fallot with ~99% accuracy.
Why the study?
Does coronary echocardiography accurately identify anomalous coronary arteries crossing the RVOT in preoperative infants with tetralogy of Fallot?
Observational (n=598)
Does coronary echocardiography accurately identify anomalous coronary arteries crossing the RVOT in preoperative infants with tetralogy of Fallot?
Answers are grounded in this paper and cite their sources.
Coronary echocardiography is a highly accurate noninvasive tool for delineating coronary anatomy in infants with tetralogy of Fallot, obviating the need for routine preoperative diagnostic cardiac catheterization.
OBJECTIVES: This study sought to determine the diagnostic accuracy and impact of the systematic use of coronary echocardiography in a large group of preoperative patients with tetralogy of Fallot (TOF). BACKGROUND: Accurate preoperative identification of an anomalous coronary artery crossing the right ventricular outflow tract (RVOT) in patients with TOF is important to prevent coronary injury during surgical repair. METHODS: A retrospective review identified 598 patients with TOF between 1983 to 1995 who underwent an echocardiogram at <2 years old before complete surgical repair. Associated diagnoses included pulmonary stenosis (n = 433), pulmonary atresia (n = 121), common atrioventricular canal (n = 17), absent pulmonary valve syndrome (n = 24) and aortopulmonary window (n = 3). RESULTS: Based on intraoperative findings, 32 patients (5.4%) were found to have a major coronary artery crossing the RVOT. The use and diagnostic performance of coronary echocardiography increased over time, while the number of patients undergoing preoperative cardiac catheterization declined. During the most recent study period (1991 to 1995, n = 274), 97% of patients underwent coronary echocardiography yielding a sensitivity of 82%, specificity of 99% and accuracy of 98.5%. Of the 18 patients with TOF and pulmonary stenosis who had abnormal coronary arteries during this period, only 6 (33%) required an extracardiac conduit as part of their complete repair. CONCLUSIONS: Coronary echocardiography is an accurate noninvasive tool to delineate coronary anatomy in infants with TOF before complete repair. Routine preoperative cardiac catheterization solely for diagnosis of coronary anatomy is not necessary. The use of an extracardiac conduit can be avoided in the majority of patients with TOF and pulmonary stenosis who have a major coronary artery crossing the RVOT.
No takes yet. Share an insight, caveat, or question.
Need et al. (2000) conducted an observational in Tetralogy of Fallot (TOF) (n=598). Coronary echocardiography was evaluated on Diagnostic accuracy for identifying an anomalous coronary artery crossing the right ventricular outflow tract. Preoperative coronary echocardiography in infants with tetralogy of Fallot yielded a sensitivity of 82%, specificity of 99%, and accuracy of 98.5% for identifying anomalous coronary arteries.
Synapse has enriched 10 related papers. Consider them for comparative context: