Answers are grounded in this paper and cite their sources.
Demonstrates improved attenuation correction in SPECT imaging, indicating enhanced quantification accuracy.
OBJECTIVE: Quantitative SPECT/CT for radiopharmaceutical therapy relies on accurate attenuation map (µ-map). Because attenuation is energy dependent, CT-derived maps must be converted to radionuclide-specific values, typically via bilinear scaling (BLS), which can introduce bias to activity quantification. To address this, we investigate the application of a kernel-based maximum-likelihood attenuation and activity (MLAA) algorithm that incorporates CT-derived anatomical features and SPECT emission data to improve µ-map accuracy. Approach: The MLAA algorithm jointly estimates µ-map and activity distribution by maximizing the Poisson log likelihood. Activity is updated using standard OSEM, while the µ-map is refined via gradient ascent from a CT-derived initialization. However, standard MLAA suffers from attenuation-activity crosstalk. To mitigate this effect, we introduce kernel MLAA, incorporating CT-based features to enhance attenuation-activity separation and constrain µ-map updates. Performance was evaluated using Monte Carlo simulations and experimental data from both a NEMA phantom and a patient scan. The entire method is implemented in the PyTomography platform, which is publicly available and GPU-accelerated for efficient 3D reconstruction. Main results: In simulations, standard MLAA exhibited strong crosstalk artifacts, whereas kernel MLAA substantially suppressed these artifacts and reduced µ-map bias, achieving an approximately 84% decrease in liver voxel-wise MAE compared with BLS. It also improved activity quantification accuracy, with the recovery-coefficient bias converging to 0.90%±0.34% across 20 noise realizations. The simulated iodinated contrast-induced activity bias decreased from 18.11% to 1.51%. Phantom and patient data validated that kernel MLAA restored perturbed µ-values, reducing mean bias from 13.6% to 0.6% (phantom) and from 13.7% to 0.3% (patient). Noise remained controlled across iterations, whereas standard MLAA tended to amplify noise. Significance: Kernel MLAA provides a robust approach for improving attenuation correction in quantitative SPECT by automatically detecting and correcting µ-map bias, offering a potential solution when CT-derived attenuation maps are biased or unreliable.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: