Answers are grounded in this paper and cite their sources.
Study predicts thermal breakthrough and optimizes parameters in geothermal systems, suggesting sustainable development strategies.
Predicting thermal breakthrough and optimizing injection-production parameters are essential for sustainable geothermal development. Traditional hydrothermal coupled simulations in porous media entail substantial computational costs, which limits their use in dense multi-parameter screening. This study develops a physics-constrained surrogate workflow for the Qihe geothermal doublet system by using COMSOL to generate hydrothermal simulation data and a deep neural network (DNN) to emulate the simulator response within a predefined operating domain. The DNN was trained on physics-driven synthetic outputs rather than independent field observations, and a 2.0 °C decrease in production temperature was used as the thermal breakthrough criterion. Under scenario-wise validation, the surrogate model achieved a test-set R2 of 0.9995 and an RMSE of 0.0351 °C, indicating accurate approximation of the deterministic simulator response within the bounded parameter space. The surrogate-based global scan identified a favorable operating region near a well spacing of 462 m, a reinjection temperature of 20 °C, and a reinjection rate of 150 m3/h. To evaluate whether this result was affected by sparse well-spacing sampling, additional COMSOL simulations were performed at 430, 440, 450, 460, 462, 470, 480, 490, and 500 m under the same reinjection temperature and rate. These simulator-based validation cases showed a continuous thermal response with increasing well spacing. The 2.0 °C thermal breakthrough time increased from 46 yr at 430 m to 61 yr at 500 m, while the 50-year cumulative heat extraction increased from 6594.2 to 6722.9 TJ. The 430 and 440 m cases experienced thermal breakthrough before the 50-year design life, whereas the 450 m case was close to the design boundary. The 460 and 462 m cases did not reach the 2.0 °C decline threshold within the 50-year design life and retained relatively high heat-extraction efficiency per unit well spacing. Therefore, the engineering recommendation is revised from a single precise optimum to a locally validated spacing interval of approximately 460–462 m under the present equivalent-porous-medium assumption. The proposed workflow does not replace hydrothermal simulation; instead, it provides a rapid screening tool that narrows the design space before targeted simulator verification and field calibration.
No takes yet. Share an insight, caveat, or question.
Du et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: