Key result
AI-powered sinus rhythm ECG model predicts paroxysmal AF with ~0.88 external AUROC.
Why the study?
Interethnic validations of AI algorithms predicting paroxysmal AF from sinus rhythm ECGs have not been widely conducted.
Does an AI-enabled sinus rhythm ECG interpretation model accurately predict paroxysmal or new-onset AF across different ethnic populations?
Observational (n=121,282)
Yes
Does an AI-enabled sinus rhythm ECG interpretation model accurately predict paroxysmal or new-onset AF across different ethnic populations?
An AI algorithm trained on sinus rhythm ECGs from a Korean population demonstrated excellent diagnostic performance for predicting paroxysmal or new-onset AF, which was successfully validated in a Brazilian cohort.
Background Previous research has demonstrated acceptable diagnostic accuracy of artificial intelligence (AI)-enabled sinus rhythm (SR) electrocardiogram (ECG) interpretation for identifying paroxysmal atrial fibrillation (AF). However, interethnic validations of the AI algorithms have not been widely conducted. Purpose We aimed to develop our own AI model for the identification of paroxysmal AF based on SR ECGs in the Korean population and to validate its diagnostic performance in Brazilian citizens. Methods We trained a Transformer-based vision network on 90% of a dataset comprising 808,194 ECGs from 121,282 patients at Seoul National University Bundang Hospital (2003-2020). The remaining 10% of the dataset was used for internal validation. The model was trained to compute a risk score for paroxysmal AF or new-onset AF within 2 years. External validation was conducted using non-AF ECGs from the CODE 15% dataset provided by the Telehealth Network of Minas Gerais, Brazil. Results In internal validation, our AI model achieved an Area Under the Receiver Operating Characteristic Curve (AUROC) of 0.911 (95% CI: 0.902 - 0.921), with a sensitivity of 78.1% and a specificity of 89.0%. Subgroup analyses showed an AUROC of 0.893 (95% CI: 0.876 - 0.909) for patients in routine health checkups or outpatient settings, and 0.854 for patients with "Normal ECG" interpretations. In external validation with the CODE 15% dataset, the AI model exhibited an AUROC of 0.884 (95% CI: 0.869-0.900), which increased to 0.906 (95% CI: 0.893-0.919) when adjusted for age and sex (Figure 1). In the subset of patients with "Normal ECG" interpretations, the AUROC was 0.826 (95% CI: 0.769-0.883), increasing to 0.861 (95% CI: 0.814-0.908) after applying the same adjustments. Conclusions Our AI-powered SR ECG interpretation model demonstrated excellent diagnostic performance in predicting paroxysmal AF, with valid performance in the Brazilian population as well. This suggests that the model has potential for broad application across different ethnic groups.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2024) conducted an observational in Paroxysmal atrial fibrillation (n=121,282). AI-enabled sinus rhythm ECG interpretation was evaluated on Prediction of paroxysmal AF or new-onset AF within 2 years (AUROC 0.911, 95% CI 0.902-0.921). An AI-powered sinus rhythm ECG interpretation model accurately predicted paroxysmal atrial fibrillation, achieving an AUROC of 0.911 internally and 0.884 (95% CI 0.869-0.900) in external validation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: