Key result
Interval pulsed-field ablation cuts microembolic signal counts ~28% vs continuous delivery in a porcine model.
Why the study?
The effects of pulsing interval versus continuous delivery and catheter contact on microembolic signals during pulsed-field ablation had not been systematically quantified.
Does interval pulsed-field ablation reduce microembolic signals compared to continuous delivery in a porcine model?
Does interval pulsed-field ablation reduce microembolic signals compared to continuous delivery in a porcine model?
Delivering pulsed-field ablation with 1-minute intervals significantly reduces the burden and size of microembolic signals compared to continuous delivery in a porcine model.
May reduce microembolic signals; hypothesis-generating in small observational data and should not yet change practice.
Background Microembolic signals (MES) are observed in carotid Doppler during pulsed-field ablation (PFA) and may contribute to silent cerebral embolism. The effects of pulsing interval versus continuous delivery (Non-interval) and catheter contact on MES have not been systematically quantified. Purpose To evaluate, in an in vivo model, the impact of pulsing interval versus continuous delivery and catheter contact on MES. Methods Eight pigs underwent left-atrial PFA at four sites (LAA, RSPV, IPV = Contact, LA free-space = Non-contact) using a circular over-the-wire pulsed-field ablation catheter. At each site, four pulses were delivered either Interval (1-min apart) or Non-interval (continuous). MES assessment: a continuous-wave Doppler probe was fixed on the common carotid artery for uninterrupted acquisition. On color Doppler, high-intensity spikes on the velocity display were identified as MES (Fig. 1A); spikes were confirmed on the extracted raw waveform from the Doppler-shift component (Fig. 1B) and counted across the four-shot set per condition. Sizes were prespecified and binned (0–10/10–20/20–30/30–40/40–50 µm). Analysis: animal-by-site pairs served as the unit (n = 32 pairs). Paired, within-animal/site comparisons estimated incidence rate ratios (IRR) with 95% confidence intervals. Primary endpoints: IRR for MES counts and MES size (median [IQR] from pooled MES and composition) for Interval vs Non-interval. Secondary endpoint: IRR for Contact vs Non-contact. This paired design minimizes between-animal variability and controls for local anatomic/flow factors, isolating delivery-strategy effects. Results Interval reduced MES vs Non-interval: overall IRR 0.72 (95% CI 0.67–0.77). Site-wise IRRs: RSPV 0.63 (0.56–0.72), IPV 0.24 (0.20–0.30), LA free-space 0.54 (0.47–0.61), LAA 1.20 (1.08–1.33) (Fig. 2A). MES size was smaller with Interval: 19.3 µm [14.0–25.5] vs 21.1 µm [14.5–26.9], p<0.001 (Fig. 2B). Secondary (Contact): overall 1.15 (1.07–1.28); during Interval 1.14 (1.01–1.37); during Non-interval 1.17 (1.05–1.30), indicating higher MES with contact across delivery strategies. Findings were consistent across sites except for LAA, where interval delivery did not reduce MES, suggesting site-specific hemodynamics may modulate embolic generation. Conclusions In a standardized porcine PFA model, 1-min interval delivery significantly reduces MES burden and MES size and may represent an effective, workflow-compatible approach to mitigate PFA-related cerebral embolic risk. Prospective clinical validation and linkage to neurological outcomes are warranted.Figure 1Figure 2
No takes yet. Share an insight, caveat, or question.
Honda et al. (2026) studied Microembolic signals during pulsed-field ablation (n=8). Interval pulsed-field ablation vs. Non-interval (continuous) pulsed-field ablation was evaluated on Incidence rate ratio for microembolic signal (MES) counts (IRR 0.72, 95% CI 0.67-0.77). Interval pulsed-field ablation reduced microembolic signal counts (IRR 0.72; 95% CI 0.67-0.77) and size (19.3 vs 21.1 µm, p<0.001) compared to continuous delivery in a porcine model.