Why the study?
Catheter ablation of PVCs traditionally involves fluoroscopy and radiation risks, making zero-fluoroscopy techniques a potentially safer alternative.
Does zero-fluoroscopy catheter ablation maintain procedural success and safety compared to conventional fluoroscopy in patients with premature ventricular contractions?
Does zero-fluoroscopy catheter ablation maintain procedural success and safety compared to conventional fluoroscopy in patients with premature ventricular contractions?
Zero-fluoroscopy catheter ablation for PVCs is a safe and effective alternative to conventional fluoroscopy, eliminating radiation exposure without compromising procedural success or increasing procedure time.
Answers are grounded in this paper and cite their sources.
Comparable acute success supports ZF feasibility in PVC ablation; leaves open confirmation via RCTs for long-term outcomes.
Background Catheter ablation of premature ventricular contractions (PVCs) is an effective treatment modality, but traditionally involves fluoroscopy, which poses radiation risks. Recently, zero-fluoroscopy (ZF) techniques have emerged as a safer alternative, especially in young patients and those requiring multiple procedures. Methods This retrospective, single-center study evaluated 150 patients who underwent PVC ablation between January 2023 and March 2025. Patients were divided into two groups: those treated with ZF (n=75) and conventional fluoroscopy (CF) (n=75). Procedural characteristics, procedure time, success rates and complications were compared. Results Acute procedural success was achieved in 79.3% overall, with comparable rates between ZF and CF groups (78.7% vs 80.0%, p = 0.84). The median procedure time was similar (88 min vs 90 min, p = 0.14), and no significant differences were observed in complication rates (4.0% vs 4.0%, p = 1.00). Stratified analysis revealed longer procedure times in anatomically complex PVC origins, particularly in LV-superior and summit regions (p < 0.001), whereas RV-inferior PVCs showed the highest success (90%) and shortest duration (p < 0.05). Univariate logistic regression identified higher PVC burden and longer procedure time as predictors of procedural failure. No coronary or atrioventricular conduction injury occurred in either group. Conclusion Zero-fluoroscopy PVC ablation is a safe and effective alternative to conventional methods. Despite longer durations in anatomically complex cases, the ZF approach avoids radiation without compromising outcomes.
No takes yet. Share an insight, caveat, or question.
Demirtas et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: