Key result
Elevated septal E/e' is linked to structural myocardial alterations on CMR following pediatric kidney transplant.
Why the study?
Cardiac complications are a leading cause of death after pediatric kidney transplantation, but defined diagnostic screening procedures are lacking, and whether echocardiographic abnormalities reflect myocardial structural changes remains unclear.
Can diastolic echocardiographic parameters identify structural myocardial alterations detected by CMR T1 mapping in pediatric kidney transplant recipients?
Cross-Sectional (n=46)
No
Can diastolic echocardiographic parameters identify structural myocardial alterations detected by CMR T1 mapping in pediatric kidney transplant recipients?
Elevated septal E/e' on routine echocardiography can identify pediatric kidney transplant recipients with underlying structural myocardial alterations, potentially guiding the use of CMR imaging.
Should not yet change practice in pediatric nephrology; leaves open prognostic value of diastolic parameters.
Background Cardiac complications are among the most common causes of death in patients after pediatric kidney transplantation (KTx), but defined diagnostic procedures identifying young patients at risk are not established. Cardiovascular magnetic resonance (CMR) imaging with native T1 mapping allows detection of diffuse myocardial alterations but is not routinely available for cardiovascular screening. Whether abnormalities detected by echocardiography reflect underlying myocardial structural changes remains unclear. Methods Pediatric KTx recipients underwent comprehensive transthoracic echocardiography and CMR imaging with native T1 mapping. Associations between echocardiographic measures and T1 values were analyzed using multivariable linear regressions. Receiver operating characteristics analyses assessed the ability of septal E/e′ to identify elevated T1 values, with area under the curve (AUC) and optimal cut-offs determined using positive likelihood ratios (LR +). Results Forty-six pediatric KTx recipients (16 ± 3.5 years old; time since KTx 7.9 ± 5.3 years) were included. Diastolic echocardiographic abnormalities were common, with 87% exhibiting at least one abnormal diastolic parameter. Septal T1 was associated with septal E/e′, A-wave, and pulmonary venous atrial reversal, while lateral T1 was associated only with septal E/e′. Optimal septal E/e′ cut-offs were 10.550 for detecting an elevated septal T1 (LR + = 7.143) and 10.630 for detecting an elevated lateral T1 (LR + = 9). Conclusions Pediatric KTx recipients with structural myocardial alterations on CMR imaging exhibit detectable abnormalities in routine echocardiographic diastolic parameters. Especially a markedly elevated septal E/e′ could identify patients at increased risk for underlying myocardial involvement and justify the use of CMR imaging in post-transplant follow-up.
No takes yet. Share an insight, caveat, or question.
Born et al. (2026) conducted a cross-sectional in Pediatric kidney transplant recipients (n=46). Echocardiographic diastolic parameters (septal E/e' ratio) vs. Age-specific reference values was evaluated on Association between septal E/e' ratio and septal native T1 on CMR (β = 8.415, p=0.042). In pediatric kidney transplant recipients, an elevated septal E/e' ratio was significantly associated with structural myocardial alterations on CMR (β = 8.415, p=0.042), identifying patients at increased risk for myocardial involvement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: