Abstract While electrochemical degradation mechanisms in lithium-ion batteries are well studied, the influence of mechanical factors remains poorly understood. Here we introduce a high-precision stack-pressure control and dilatometry tool to apply a uniform and constant stack pressure on electrodes independent of electrode swelling. By increasing stack pressure fourfold over typical initial values, we double the lifetime of graphite ‖ LiNi 0.8 Mn 0.1 Co 0.1 O 2 cells, an industrially relevant battery chemistry, without altering active materials or electrolytes. This suggests that many lithium-ion batteries operate under sub-optimal stack-pressure conditions, leading to curtailed lifetimes. We demonstrate that different degradation mechanisms emerge outside the optimal pressure window: low stack pressure accelerates cathode cracking, whereas high pressure promotes lithium plating. Our findings highlight coupled mechanical–electrochemical degradation mechanisms and identify stack-pressure optimization as a practical solution for increasing cycling stability.
Wang et al. (Mon,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: