Key result
Implantable cardioverter defibrillators for patients with coronary artery disease and ejection fraction <=30% sparked debate over CMS coverage restricted to those with QRS >=120 ms.
Why the study?
Should all patients with an ejection fraction ≤30% because of coronary artery disease receive ICDs, regardless of other risk-stratifying tests?
Should all patients with an ejection fraction ≤30% because of coronary artery disease receive ICDs, regardless of other risk-stratifying tests?
Answers are grounded in this paper and cite their sources.
This editorial discusses the controversy and CMS coverage decision regarding prophylactic ICD implantation in patients with ischemic cardiomyopathy and EF ≤30% based on the MADIT II trial.
long-awaited decision on coverage of implantable cardio-verter defibrillators (ICDs) for patients meeting the clinical profile of the second Multicenter Automated Defibrillator Implantation Trial (MADIT II).1 CMS offered a split deci-sion, extending coverage only to Medicare patients meeting the MADIT II inclusion and exclusion criteria and having a QRS duration 120 ms. Information on and a timeline of the CMS coverage determination process are publicly available at their World Wide Web site,2 which has a link to a detailed decision memorandum.3 Although versions of the “MADIT II debate ” have already taken place in many forums, we believe several issues regarding both the trial and the CMS decision require further discussion. We will focus on the intertwined issues of risk stratification and cost that have arisen repeat-edly in this debate. The MADIT II debate boils down to the question posed by Dr Alfred Buxton in a recent editorial4: Should all patients with an ejection fraction 30 % because of coronary artery disease receive ICDs, regardless of other risk-stratifying tests? Dr Buxton suggested the answer to this question should be “no”: “I believe it is premature to recommend ICDs on the basis of only one trial that may not be generalizable to all patients.”4 Dr Buxton’s remarks and the CMS decision stand in contrast to the otherwise unimpeded march the MADIT II results have made toward clinical acceptance. After publica-tion of MADIT II, the Food and Drug Administration quickly approved the Guidant ICD used in the trial for this new
No takes yet. Share an insight, caveat, or question.
Reynolds et al. (2003) conducted an editorial in Coronary artery disease. Implantable cardioverter defibrillators (ICDs) was evaluated. Implantable cardioverter defibrillators for patients with coronary artery disease and ejection fraction <=30% sparked debate over CMS coverage restricted to those with QRS >=120 ms.
Synapse has enriched 10 related papers. Consider them for comparative context: