Key result
Contrast balloon sizing guides successful downsized valve selection during type 1 BAV TAVR.
Why the study?
Valve size selection for TAVR with a balloon-expandable valve in bicuspid aortic valve involves trade-offs among risks of aortic rupture, paravalvular leak, and inadequate valve expansion.
Does balloon predilatation with contrast injection using a balloon slightly smaller than the smaller candidate valve size guide optimal balloon-expandable valve size selection in patients with type 1 bicuspid aortic valve with a tapered configuration undergoing TAVR?
Case Report (n=2)
Does balloon predilatation with contrast injection using a balloon slightly smaller than the smaller candidate valve size guide optimal balloon-expandable valve size selection in patients with type 1 bicuspid aortic valve with a tapered configuration undergoing TAVR?
In patients with tapered type 1 bicuspid aortic valves where CT measurements border between two consecutive balloon-expandable valve sizes, observing balloon indentation without left ventricular contrast backflow during predilatation with a slightly smaller balloon supports choosing the smaller valve size to prevent underexpansion and aortic root rupture.
Answers are grounded in this paper and cite their sources.
May support smaller valve selection to avoid underexpansion in tapered type 1 BAV; leaves open prospective validation before adoption.
Valve size selection for transcatheter aortic valve replacement using a balloon-expandable valve in a bicuspid aortic valve (BAV) involves a trade-off among the risks of aortic rupture, residual paravalvular leak, and inadequate valve expansion. We report 2 cases of type 1 BAVs with a tapered configuration that created challenges regarding valve size selection. Two consecutive valve sizes were considered based on multidetector computed tomography measurements. Therefore, predilatation with contrast injection was performed using a balloon that was slightly smaller than the smaller of the 2 valve sizes. These cases suggest that a smaller valve should be selected when balloon indentation is observed without contrast backflow into the left ventricle because selecting the larger valve may result in insufficient expansion. Balloon predilatation with contrast injection may be a useful strategy for determining the appropriate valve size for transcatheter aortic valve replacement using a balloon-expandable valve in type 1 BAVs with a tapered configuration.
No takes yet. Share an insight, caveat, or question.
Satomi et al. (2026) conducted a case report in Severe aortic stenosis with type 1 bicuspid aortic valve (BAV) and tapered configuration (n=2). Balloon predilatation with contrast injection using a semicompliant balloon slightly smaller than the smaller candidate valve size (18-mm or 22-mm) to guide balloon-expandable valve selection was evaluated on Adequate balloon-expandable transcatheter heart valve expansion without aortic rupture or paravalvular leak. Balloon sizing with contrast injection guided type 1 BAV TAVR, showing smaller valve selection (20-mm vs 26-mm) achieved adequate expansion when balloon indentation occurred without contrast backflow.