Key result
A single tapered Coons dilator significantly reduced device deployment time (15.1 vs 23.5 min, p<0.0005) and total time compared to sequential serial dilation for Micra pacemaker implantation.
Why the study?
Micra leadless pacemaker placement requires a 23 French introducer sheath, prompting evaluation of whether a single tapered Coons dilator improves outcomes compared with sequential serial dilatation.
Does a single tapered Coons dilator reduce device deployment time and total time compared to sequential serial dilatation in patients undergoing Micra leadless pacemaker implantation?
Cohort (n=84)
Does a single tapered Coons dilator reduce device deployment time and total time compared to sequential serial dilatation in patients undergoing Micra leadless pacemaker implantation?
Absolute Event Rate: 15.1% vs 23.5%
p-value: p=<0.0005
Using a single tapered Coons dilator for Micra leadless pacemaker implantation significantly reduces deployment time, total procedure time, and cost compared to sequential serial dilatation.
May shorten leadless pacemaker deployment time; leaves open safety and generalizability in larger trials.
OBJECTIVES: Comparison of outcomes, device deployment time (DT), and total time (TT) using a single tapered Coons dilator versus sequential serial dilation for implantation of the Micra leadless pacemaker. BACKGROUND: Micra leadless pacemaker placement requires a 23 French Micra introducer sheath (MIS) for percutaneous delivery. We sought to evaluate outcomes with use of a single tapered Coons dilator (CD) versus sequential serial dilatation (SD) method to facilitate insertion of the Micra introducer sheath. METHODS: 35 patients were included in the SD arm and 49 in the CD arm. DT and TT were recorded in minutes and cost in dollars. Analysis was performed using independent t-test between two groups and one-way ANOVA to evaluate inter-operator variability in the CD arm. RESULTS: Both DT and TT were significantly lower for the CD arm (15.1 ± 5.1 vs 23.5 ± 9.3, p < 0.0005 and 29.9 ± 14 vs 39.3 ± 13.5 min, p = 0.000374; respectively). The cost was also significantly lower using a CD versus SD. There was no inter-operator variability in the CD arm between 6 operators (p = 0.177 for DT and p = 0.304 for TT). No complications occurred in the SD arm. There were 3 vascular access site complications in the CD arm, all of which occurred early in the operator's experience. CONCLUSION: Coons dilator is an efficient and cost-effective method for vascular dilatation to facilitate Micra leadless pacemaker insertion. Rate of complications is low and expected to improve with greater experience.
No takes yet. Share an insight, caveat, or question.
Mohammed et al. (2020) conducted a cohort in Micra leadless pacemaker implantation (n=84). Single tapered Coons dilator vs. Sequential serial dilatation was evaluated on Device deployment time (minutes) (p=<0.0005). A single tapered Coons dilator significantly reduced device deployment time (15.1 vs 23.5 min, p<0.0005) and total time compared to sequential serial dilation for Micra pacemaker implantation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: