Evaluates accuracy of digital impressions in maxillary incisor preparations, suggesting clinical viability of three scanners.
Introduction: The accuracy of intraoral scanners (IOSs) in capturing a Biologically Oriented Preparation Technique (BOPT) remains uncertain. The aim of this study was to evaluate the accuracy of digital impressions obtained with three intraoral scanners for recording BOPT preparations. Methods: A maxillary central incisor was prepared following BOPT. After temporization, a conventional polyvinyl siloxane impression was scanned with a desktop scanner to obtain a reference model. Forty-two scans (n D 14 per scanner) were recorded with three IOSs—Trios 3, Sirios, and Helios 680—by a single operator under standardized conditions. Accuracy was assessed using Geomagic Control X by calculating 3D surface deviation (RMS). Data normality was tested using Shapiro–Wilk and Kolmogorov–Smirnov tests. Trueness was compared with one-way ANOVA, and precision was evaluated using intraclass correlation coefficients (α ≤ 0.05). Results: Sirios showed the highest trueness in both analyses but statistically unsignificant (p < 0.05). Conclusions: All IOSs achieved clinically acceptable trueness for full preparations, with only Sirios meeting the threshold at the margin. Precision was similar across scanners.
No takes yet. Share an insight, caveat, or question.
Habli et al. (2026) studied this question.