Investigates seismic response control in steel frames using a novel friction damper, highlighting its effectiveness.
The inerter-based response amplification device for dampers has been proposed to enhance seismic resilience, yet its real-world dynamic behavior lacks experimental validation. This study investigates a Cam-Type Response-Amplification Friction Damper (CRAFD) through shaking table test of full-scale steel frame subjected to nine seismic records (including near/far-field events). Key findings reveal that the CRAFD achieves: (1) Target amplification of friction forces (8 kN vs lateral FD’s 1.2 kN) and inertial mass, inducing significant negative stiffness in the primary structure; (2) The natural frequency decreased by a maximum of 34% (from 2.9 Hz to 1.91 Hz) under 0.4 g inputs, and the equivalent damping ratio was significantly improved compared to traditional FD; (3) Higher displacement mitigation and acceleration reduction by maintaining sliding status, which elevates energy dissipation ratio and prevents structural damage; (4) CRAFD suppresses out-of-plane deformation in V-shape linkages. These results validate CRAFD’s efficacy in seismic response control for engineering applications.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: