Evaluates thermal comfort improvements in educational buildings, indicating potential for energy savings.
The construction sector is responsible for approximately 38% of global CO2 emissions, driven primarily by energy demand for thermal comfort. This research evaluated the implementation of a Passive Climate Control System (PCCS) based on circular economy principles. This system acts as a thermal buffer composed of recycled PET bottles filled with 500 mL of water and a reflective coating, installed on the roof slab. Through a case–control study in Veracruz, Mexico, hygrothermal performance was monitored for ten months. The results demonstrated the superiority of the PCCS over the conventional slab: in autumn–winter, temperature fluctuations were reduced by 26.7%, while in spring–summer, the maximum temperature was limited by 1.3 °C during the daytime peak. Fractal analysis confirmed that the PCCS promotes a homogeneous thermal distribution (Fd ≤ 1.255), maintaining internal conditions within the comfort zone. The implementation of this PCCS, based on waste valorization, is a robust and sustainable solution that offers a viable alternative to active climate control. It promotes hygrothermal comfort and reduces energy consumption, aligning with the objectives of Clean Technology and building efficiency.
No takes yet. Share an insight, caveat, or question.
Vega et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: