Answers are grounded in this paper and cite their sources.
Shows battery-aware control improves performance in battery chargers, suggesting effective energy management.
This paper presents a battery-aware control framework for a single-phase integrated battery charger (IBC) for electric vehicles, in which the traction system is reused as part of the charging hardware. The proposed charger consists of a stator-assisted bridgeless totem-pole power-factor-correction AC–DC stage and a bidirectional buck–boost DC–DC stage connected to a 48 kWh, 400 V lithium-ion battery pack. The battery pack is modeled using a lookup-table-based equivalent circuit model with state-of-charge- and temperature-dependent open-circuit voltage and impedance parameters. A conventional double-loop PI controller is used as the baseline, while the proposed strategy combines nonlinear model predictive control, an extended Kalman filter, and lookup-table-based battery parameterization to regulate charging current under electrical and thermal constraints. The system is evaluated under 7 kW, 230 V/32 A and 22 kW, 230 V/96 A charging cases using average-model simulations, switching-model transient simulations, and finite element thermal assessment of the induction motor stator. The average-model results show stable charging from 20% to 80% SOC, with charging times of approximately 275 min at 7 kW and 90 min at 22 kW. The EKF provides bounded battery state estimation, with maximum SOC estimation errors of approximately 1.3% and 2.0% for the 7 kW and 22 kW cases, respectively, while the core-temperature estimation error converges close to zero. The switching-model results confirm feasible duty-command behavior, bounded battery-current tracking error, and a representative DC-link ripple of approximately 8 Vpp. During grid-voltage reduction, the charging current is reduced to keep the grid-current envelope within the intended limit. FEM results show that charging-only motor temperatures remain low, reaching approximately 27.39 °C at 7 kW and 38.82–38.85 °C at 22 kW. The most critical charging-related thermal case occurs at 22 kW after one hour of full-load motor operation with a 40 °C initial condition, reaching approximately 92.32 °C. Overall, these simulation-based findings support the feasibility of the proposed NMPC–EKF–LUT framework as a battery-aware supervisory control strategy for single-phase IBC operation. The proposed controller improves constraint-aware, battery state-based decision-making, while switching ripple and motor thermal response are mainly governed by the power stage, feasible current trajectory, and initial thermal condition.
No takes yet. Share an insight, caveat, or question.
Bousungnoen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: