Answers are grounded in this paper and cite their sources.
Background Susceptibility-induced distortion in ssEPI prostate DWI can degrade lesion conspicuity, ADC estimation, and confidence in prostate MRI interpretation. Conventional correction strategies typically require additional acquisitions and may be limited in severe artifact settings. Purpose To develop a physics-informed deep learning framework, Distortion-Guided Restoration (DGR), for acquisition-free correction of single-shot echo-planar imaging (ssEPI) distortions in prostate diffusion-weighted imaging (DWI). Material and Method DGR was proposed to learn the inverse of a physically simulated ssEPI distortion process. Clinical prostate DWI and T2-weighted (T2W) images from 408 3T MR examinations originating from two clinical datasets, acquired on Siemens 3T MAGNETOM Vida and Biograph mMR scanners, were used for paired distorted/undistorted training data across low-b DWI (b = 50 s/mm2), scanner-provided apparent diffusion coefficient (ADC) maps. The restoration network integrates a convolutional neural network (CNN) - based geometric correction module with a conditional diffusion refinement module, both guided by co-registered T2W images. Model selection and benchmarking were performed on a held-out synthetic test set (n = 34), against conventional algorithms using correction field mapping (FSL FUGUE and TOPUP). Model performance was evaluated in a retrospective study on 34 clinical scans with severe susceptibility artifacts drawn from the same clinical datasets, using quantitative image metrics and blinded radiologist scoring. Results On synthetic data, the proposed DGR model achieved the highest peak signal-to-noise ratio (PSNR) and lowest normalized mean squared error (NMSE) across low-b DWI (0.089; 95% CI: 0.072-0.105) and ADC maps (0.062; 95% CI: 0.053-0.072), outperforming FSL TOPUP and FUGUE (all p < 0.001). In the 34 clinical cases affected by susceptibility artifacts, including 16 cases with histologically confirmed lesions (16/34, 47.1%). DGR substantially improved geometric fidelity (2.74 to 3.29), identified all histologically confirmed lesions(16/16, 100%), and enhanced overall image quality and diagnostic confidence (all p < 0.001). Conclusion This proof-of-concept study suggests that a physics-informed hybrid CNN–diffusion framework offers a practical and acquisition-free solution for correcting severe prostate DWI distortions. It warrants further development for clinical utility and implementation.
No takes yet. Share an insight, caveat, or question.
Long et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: