Key result
Incomplete IJV collapse on sniff detects elevated right atrial pressure with ~84% sensitivity.
Why the study?
Accurate fluid status estimation is paramount in heart failure, leading investigators to test whether bedside ultrasound of the IJV and SCV could reliably estimate RAP.
Does bedside ultrasound assessment of the internal jugular and subclavian veins accurately estimate invasively measured right atrial pressure in spontaneously breathing adults?
Cross-Sectional (n=72)
Yes
Does bedside ultrasound assessment of the internal jugular and subclavian veins accurately estimate invasively measured right atrial pressure in spontaneously breathing adults?
Bedside ultrasound evaluation of the internal jugular vein offers a reliable, superficial alternative to the inferior vena cava for non-invasively estimating right atrial pressure.
May support bedside IJV assessment for RAP estimation; leaves open prospective validation before clinical adoption.
Accurate estimation of fluid status is paramount in patients with heart failure. We hypothesized that bedside ultrasound assessment of the internal jugular vein (IJV) and subclavian vein (SCV) could reliably estimate right atrial pressure (RAP). Prospectively enrolled patients were positioned supine. IJV was imaged at the apex of the right sternocleidomastoid muscle and SCV was imaged at the lateral third of the right clavicle. Using M-mode on a portable ultrasound machine, the maximum (Dmax) and minimum (Dmin) anteroposterior diameters were noted during normal breathing. Respiratory variation in diameter (RVD) was calculated as [(Dmax – Dmin)/Dmax] and expressed as percent. Collapsibility was assessed with sniff maneuver. Patients then underwent right heart catheterization and their findings were correlated with above. Total of 72 patients were enrolled with mean age 61 years, mean BSA 1.9 m2, and left ventricular ejection fraction 45 ± 20%. Elevated RAP≥ 10 mmHg was associated with dilated IJV Dmax(1.0 vs. 0.7cm, p = 0.001), less RVD with resting respiration (14% vs. 40% for IJV, p = 0.001 and 24% vs. 45% for SCV, p = 0.001), and reduced likelihood of total collapsibility with sniff (16% vs. 66% patients for IJV, p = 0.001 and 25% vs. 57% patients for SCV, p = 0.01). For RAP ≥10 mmHg, lack of IJV complete collapsibility with sniff had a sensitivity of 84% while IJV Dmax > 1cm and RVD <50% had a specificity of 80%. The IJV and SCV diameters and their respiratory variation are reliable in estimating RA pressure.
No takes yet. Share an insight, caveat, or question.
Vaidya et al. (2021) conducted a cross-sectional in Patients scheduled for right heart catheterization (n=72). Bedside ultrasound of internal jugular and subclavian veins vs. Invasive right heart catheterization was evaluated on Right atrial pressure ≥ 10 mmHg estimation by lack of IJV collapsibility with sniff (Sensitivity 84%, Specificity 66%, ROC AUC 0.750, p=0.001). Lack of internal jugular vein complete collapsibility on bedside ultrasound sniff maneuver demonstrated 84% sensitivity for estimating invasive right atrial pressure ≥10 mmHg.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: