Key result
Pulsatile lower limb venous Doppler flow was highly specific (94%) but had low sensitivity (46%) for detecting elevated right atrium pressure (>8 mm Hg) indicative of right-sided heart failure.
Why the study?
Does pulsatile lower limb venous Doppler flow correlate with elevated right atrium pressure in patients undergoing venous Doppler imaging?
Observational (n=51)
Does pulsatile lower limb venous Doppler flow correlate with elevated right atrium pressure in patients undergoing venous Doppler imaging?
Pulsatile venous Doppler flow in the lower limbs is highly specific but poorly sensitive for detecting elevated right atrial pressure (>8 mm Hg).
May support ruling in elevated RAP but not exclusion due to low sensitivity; leaves open prospective validation before clinical adoption.
OBJECTIVE: The purpose of this study was to determine if pulsatile flow in lower limbs as seen on venous Doppler waveforms correlates with increased right atrium pressure. MATERIALS AND METHODS: Of 429 patients who, over a 14-month period, underwent venous Doppler imaging of the lower limb to exclude deep venous thrombosis, 343 records were available for review at the time of the study. Of these, 74 had right atrium pressure measurements available for correlation. Seventeen patients were excluded because of thrombosis in the common femoral vein. Six other patients were also excluded because the time difference between the Doppler and the correlative studies was more than 4 weeks. The remaining 51 patients constituted the study subjects. In 18 of these, the right atrium pressure was measured within 1 week, 31 within 2 weeks, 42 within 3 weeks, and 51 within 4 weeks. In the study, we evaluated the three major veins of the lower limb (the common femoral, superficial femoral, and popliteal) by venous Doppler imaging. Data from only the common femoral vein were included in our analysis because this vessel was the least involved with thrombosis. The findings were correlated with the presence or absence of right-sided heart failure as determined by right atrium pressure measurement. A Doppler waveform was considered pulsatile when it had a cyclic retrograde component. A right atrium pressure of more than 8 mm Hg was considered elevated. RESULTS: Of 51 patients, 17 (33%) had pulsatile lower limb venous Doppler flow waveforms and 33 (65%) had elevated right atrium pressure. We found a statistically significant correlation between the presence of these abnormal waveforms and elevated right atrium pressure. The sensitivity of lower limb venous Doppler imaging for detecting right-sided heart failure as determined by right atrium pressure measurement was 46%, specificity was 94%, positive predictive value was 94%, negative predictive value was 50%, and accuracy was 65%. CONCLUSION: Pulsatile lower limb venous Doppler waveform correlates well with right-sided heart failure, as indicated by a right atrium pressure measurement of more than 8 mm Hg. However, because of its low sensitivity, lower limb venous Doppler imaging cannot be used to screen for right-sided heart failure.
No takes yet. Share an insight, caveat, or question.
Abu‐Yousef et al. (1996) conducted an observational in Suspected deep venous thrombosis / Right-sided heart failure (n=51). Pulsatile lower limb venous Doppler flow vs. Non-pulsatile venous Doppler flow was evaluated on Elevated right atrium pressure (>8 mm Hg). Pulsatile lower limb venous Doppler flow was highly specific (94%) but had low sensitivity (46%) for detecting elevated right atrium pressure (>8 mm Hg) indicative of right-sided heart failure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: