An analytical process model for predicting the layer height and wall width from the process parameters was developed for wire + arc additive manufacture of Ti-6Al-4V, which includes inter-pass temperature and material properties. Capillarity theory predicted that cylindrical deposits were produced where the wall width was less than 12 mm (radius <6 mm) due to the large value of the surface tension. Power was predicted with an accuracy of ±20% for a wide range of conditions for pulsed TIG and plasma deposition. Interesting differences in the power requirements were observed where a surface depression was produced with the plasma process due to differences in melting efficiency and/or convection effects. Finally, it was estimated the impact of controlling the workpiece temperature on the accuracy of the deposit geometry.
No takes yet. Share an insight, caveat, or question.
Ríos et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: