Key points are not available for this paper at this time.
Traditional CO 2 reduction systems often fail in an alkaline environment due to the interaction of CO 2 with a high-pH electrolyte, where carbonate and bicarbonate ion formation results in potassium-containing salt precipitation. The presence of the salt crystals causes a reduction in the selectivity of the electrolyzer toward CO 2 conversion. Here, the critical operational variables, which elicit the salting out process, are investigated (i.e., ion transport). When the electrolyzer exceeds a critical current density, H 2 evolution dominates CO 2 reduction due to salt formation, which is confirmed by postmortem cross-sectional SEM-EDS of the electrode. The critical current density decreases with an increasing membrane thickness or anolyte ionic strength. Cathode salt formation is mediated by the unmitigated crossover of cations from the anolyte to the cathode across an anion exchange membrane, through which cations are imperfectly excluded. It is likely that electric field-driven migration promotes an increase in concentration of potassium across the membrane, until, at the critical current density for that electrolyzer arrangement, the concentration of potassium and bicarbonate ions exceeds the solubility limit of KHCO 3, leading to salt precipitation.
Simonson et al. (Wed,) studied this question.