• Flexible antenna Design: a flexible and wearable antenna with a defected ground structure (DGS) was developed, optimized, and experimentally validated for use in wearable devices. • Optimization Process: the antenna was optimized using the Nelder-mead simplex Algorithm. It operates at 2.185 GHz with strong signal quality (|S11| ≈ –22.34 dB) and a peak gain of 5.57 dBi. • Safety Assurance: SAR (Specific absorption Rate) analysis showed the antenna meets international safety standards, proving it is safe and effective for wearable applications. • Performance during Bending: the antenna's performance was tested under different bending conditions. It worked consistently well, showing it is both robust and flexible. • On-Body Testing: the antenna was tested on various body parts, including the hand, leg, and chest. It performed reliably in all cases, confirming its suitability for wearable use. • Applications in 5G: the results show that this antenna is ideal for wearable devices operating in the 5 G Sub-6 GHz frequency range, offering excellent performance, flexibility, and safety. This study introduces a Nelder-Mead Simplex Algorithm based low-profile, flexible, and wearable defected ground structure (DGS)-loaded deformed microstrip antenna for Sub-6 GHz 5 G applications. It is fabricated on a low-loss 20 mil Rogers RT/Duroid 5880 substrate and the antenna demonstrates robust performance with reflection coefficient magnitude (|S 11 |) of –22.34 dB with peak gain of about 5.57 dBi at resonant frequency ( f r ) of 2.185 GHz. Comprehensive key performance metrics such as |S 11 |, far-field gain patterns, and specific absorption rate (SAR) of the proposed antenna is demonstrated. The SAR for 1 g and 10 g tissues at various separation distances are analyzed and presented by utilizing human multilayer phantom model with antenna. Additionally, the lowest SAR is measured to be 0.0959 W/kg for 1 g of tissue and 0.0755 W/kg for 10 g of tissue when the antenna is placed 0.291λ 0 away from the model. The study also explores the proposed antenna performance under various bending conditions for the conformability analysis and in different on-body scenarios, with placement on the hand, leg, and chest. The measured |S 11 | values, particularly strong on the chest, underscore the antenna effectiveness for wearable technology.
No takes yet. Share an insight, caveat, or question.
Soni et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: