The ordinary and extraordinary refractive indices of rutile (TiO2) have been measured as a function of temperature and wavelength within the ranges 30–160 °C and 454–1330 nm, respectively, by using a prism coupling reflectivity setup. The measurements have been done with regard to the accurately known indices of a congruent LiNbO3 substrate. The index values are given with the same accuracy as that of the substrate taken as reference, i.e., ±0.001 at room temperature and ±0.003 at 160 °C. The room temperature values are coincident with those previously published by other workers. Sellmeier-like equations which include wavelength and temperature as variables within the studied ranges are given for both indices.
No takes yet. Share an insight, caveat, or question.
Rams et al. (1997) studied this question.