Key result
An endoscope-assisted technique for endovascular placement of a ventriculoatrial shunt was successfully performed in 5 patients with complicated shunt malfunction histories, with 0% complications.
Why the study?
Does an endoscope-assisted technique improve the safety and accuracy of ventriculoatrial shunt placement in patients with complicated histories of shunt malfunction?
Case Report (n=5)
Does an endoscope-assisted technique improve the safety and accuracy of ventriculoatrial shunt placement in patients with complicated histories of shunt malfunction?
An endoscope-assisted technique using venography guidance facilitates accurate placement of ventriculoatrial shunts in patients with a history of failed shunts.
May aid complex atrial shunt revisions; hypothesis-generating in small series, needs prospective validation.
Atrial shunt revision surgeries are sometimes difficult due to venous occlusion and neck scarring. A direct approach guided by venography facilitates exposure and guarantees accurate placement of the distal catheter. Five patients with complicated histories of shunt malfunction were treated using an endoscope-assisted technique. The distal end of an atrial catheter was advanced into the atrium after having been connected to a venous catheter of a slightly smaller diameter than the one previously advanced from the femoral vein through the atrium. Once the position of the atrial catheter was confirmed fluoroscopically, the venous catheter was detached and removed. No complications developed in any patient. This endoscope-assisted technique offers three advantages: it demonstrates the patency of the jugular vein through venography, facilitates identification of the internal jugular vein in the neck, and provides a quick way to confirm that the distal end of the atrial catheter has been placed correctly. This technique should be considered for use in patients with a history of failed atrial shunts.
No takes yet. Share an insight, caveat, or question.
Gonzalez et al. (2007) conducted a case report in Complicated histories of shunt malfunction (n=5). Endoscope-assisted technique for ventriculoatrial shunt placement was evaluated on Complications. An endoscope-assisted technique for endovascular placement of a ventriculoatrial shunt was successfully performed in 5 patients with complicated shunt malfunction histories, with 0% complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: