Implantation of the D-Shant atrial shunt device in symptomatic HFrEF patients significantly improved 6-minute walk distance by a mean of 54.1 m (95% CI 45.9-62.3; p<0.0001) at 1 year.
Cohort (n=120)
Yes
Does the D-Shant atrial shunt device improve functional capacity and symptoms in patients with symptomatic HFrEF?
In a single-arm study, the D-Shant atrial shunt device was associated with significant improvements in functional capacity, quality of life, and heart failure hospitalizations at 1 year in patients with HFrEF.
Mean Difference: 54.1 (95% CI 45.9–62.3)
p-value: p=<0.0001
BACKGROUND: Evidence for atrial shunt devices in heart failure with reduced ejection fraction (HFrEF) is limited. This study aimed to evaluate the 1-year clinical and haemodynamic outcomes associated with an atrial shunt device in this population. METHODS: In this prospective, multicentre, single-arm cohort study of an interatrial shunt in heart failure with reduced ejection fraction (SUSTAIN-HF), 120 symptomatic HFrEF patients (left ventricular ejection fraction; LVEF ≤40%) on guideline-directed medical therapy were enrolled across 16 centres in China. The intervention was implantation of the D-Shant atrial shunt device. Prespecified primary outcomes were the changes from baseline to 1 year in 6 min walk distance (6MWD) and New York Heart Association (NYHA) functional class. Secondary outcomes included quality of life (Kansas City Cardiomyopathy Questionnaire; KCCQ), echocardiographic parameters and adjudicated adverse events. RESULTS: Between October 2017 and December 2021, 120 patients were enrolled. At 1-year follow-up, implantation of the shunt device was associated with significant improvements in clinical outcomes. The mean 6MWD increased by 54.1 m (95% CI 45.9 to 62.3; p<0.0001), and the KCCQ overall score was improved by 16.5 points (95% CI 13.9 to 19.1; p<0.0001). The proportion of patients in NYHA class III/IV decreased from 95.0% to 22.9% (p<0.0001). The annualised rate of heart failure hospitalisation was reduced from 3.3 to 0.3 events per patient-year (p<0.0001). LVEF increased by 9.0% (95% CI 6.9% to 11.1%; p<0.0001). The primary safety endpoint, a composite of major adverse cardiac and device-related events at 1 year, occurred in 15.0% of patients, driven primarily by cardiovascular death. CONCLUSIONS: In this prospective cohort study of symptomatic HFrEF patients, treatment with the D-Shant atrial shunt device was associated with significant improvements in functional capacity, quality of life and rates of heart failure hospitalisation at 1 year. The single-arm design precludes definitive conclusions on treatment efficacy, underscoring the need for randomised, sham-controlled trials.
Zhang et al. (Fri,) conducted a cohort in heart failure with reduced ejection fraction (HFrEF) (n=120). D-Shant atrial shunt device was evaluated on changes from baseline to 1 year in 6 min walk distance (6MWD) and New York Heart Association (NYHA) functional class (MD 54.1, 95% CI 45.9 to 62.3, p=<0.0001). Implantation of the D-Shant atrial shunt device in symptomatic HFrEF patients significantly improved 6-minute walk distance by a mean of 54.1 m (95% CI 45.9-62.3; p<0.0001) at 1 year.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: