Key result
Automated deep learning improves regional longitudinal strain reproducibility by ~35% over semi-automatic measurements.
Why the study?
The clinical utility of regional strain measurements in echocardiography is challenged by suboptimal reproducibility.
Does a fully automated deep learning method improve the test-retest reproducibility of regional longitudinal strain compared to standard semi-automatic measurements in patients undergoing echocardiography?
Cross-Sectional (n=80)
Yes
Does a fully automated deep learning method improve the test-retest reproducibility of regional longitudinal strain compared to standard semi-automatic measurements in patients undergoing echocardiography?
A fully automated deep learning point-tracking algorithm significantly improves the test-retest reproducibility and time-efficiency of regional longitudinal strain measurements compared to manual initialization using standard semi-automatic software.
Answers are grounded in this paper and cite their sources.
May support more consistent regional strain use in echocardiography; hypothesis-generating and requires prospective validation before practice change.
Aims The clinical utility of regional strain measurements in echocardiography is challenged by suboptimal reproducibility. In this study, we aimed to evaluate the test–retest reproducibility of regional longitudinal strain (RLS) per coronary artery perfusion territory (RLSTerritory) and basal-to-apical level of the left ventricle (RLSLevel), measured by a novel fully automated deep learning (DL) method based on point tracking. Methods and results We measured strain in a dual-centre test–retest data set that included 40 controls and 40 patients with suspected non-ST elevation acute coronary syndrome. Two consecutive echocardiograms per subject were recorded by different operators. The reproducibility of RLSTerritory and RLSLevel measured by the DL method and by three experienced observers using semi-automatic software (2D Strain, EchoPAC, GE HealthCare) was evaluated as minimal detectable change (MDC). The DL method had MDC for RLSTerritory and RLSLevel ranging from 3.6 to 4.3%, corresponding to a 33–35% improved reproducibility compared with the inter- and intraobserver scenarios (MDC 5.5–6.4% and 4.9–5.4%). Furthermore, the DL method had a lower variance of test–retest differences for both RLSTerritory and RLSLevel compared with inter- and intraobserver scenarios (all P < 0.001). Bland–Altman analyses demonstrated superior reproducibility by the DL method for the whole range of strain values compared with the best observer scenarios. The feasibility of the DL method was 93% and measurement time was only 1 s per echocardiogram. Conclusion The novel DL method provided fully automated measurements of RLS, with improved test–retest reproducibility compared with semi-automatic measurements by experienced observers. RLS measured by the DL method has the potential to advance patient care through a more detailed, more efficient, and less user-dependent clinical assessment of myocardial function.
No takes yet. Share an insight, caveat, or question.
Nyberg et al. (2024) conducted a cross-sectional in Controls and suspected non-ST elevation acute coronary syndrome (n=80). Fully automated deep learning method for regional longitudinal strain vs. Semi-automatic method by experienced observers was evaluated on Minimal Detectable Change (MDC) for regional longitudinal strain per territory (RLSTerritory) (p=<0.001). A novel fully automated deep learning method improved test-retest reproducibility of regional longitudinal strain by 33-35% with lower variance of differences compared to semi-automatic measurements by experienced observers (p<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: