Key result
Surface engineering of cardiomyocytes with a streptavidin-biotin adhesion system achieved an 80% success rate for measuring calcium release transients compared to 20% without surface engineering.
Why the study?
Primary cardiomyocytes often move during rapid solution changes to compromise quantitative measures in optical imaging, requiring improved immobilization to glass.
Answers are grounded in this paper and cite their sources.
Engineering cardiomyocytes with a streptavidin-biotin adhesion system significantly improves cell retention and functional analysis success rates during rapid fluid changes in vitro.
In vitro analysis of primary isolated adult cardiomyocyte physiological processes often involves optical imaging of dye-loaded cells on a glass substrate. However, when exposed to rapid solution changes, primary cardiomyocytes often move to compromise quantitative measures. Improved immobilization of cells to glass would permit higher throughput assays. Here, we engineer the peripheral membrane of cardiomyocytes with biotin to anchor cardiomyocytes to borosilicate glass coverslips functionalized with streptavidin. We use a rat cardiac myoblast cell line to determine general relationships between processing conditions, ligand density on the cell and the glass substrate, cellular function, and cell retention under shear flow. Use of the streptavidin-biotin system allows for more than 80% retention of cardiac myoblasts under conventional rinsing procedures, while unmodified cells are largely rinsed away. The adhesion system enables the in-field retention of cardiac cells during rapid fluid changes using traditional pipetting or a modern microfluidic system at a flow rate of 160 mL/min. Under fluid flow, the surface-engineered primary adult cardiomyocytes are retained in the field of view of the microscope, while unmodified cells are rinsed away. Importantly, the engineered cardiomyocytes are functional following adhesion to the glass substrate, where contractions are readily observed. When applying this adhesion system to cardiomyocyte functional analysis, we measure calcium release transients by caffeine induction at an 80% success rate compared to 20% without surface engineering.
No takes yet. Share an insight, caveat, or question.
Davis et al. (2021) studied this question. Streptavidin-biotin adhesion system vs. Unmodified cells was evaluated on Success rate of measuring calcium release transients by caffeine induction. Surface engineering of cardiomyocytes with a streptavidin-biotin adhesion system achieved an 80% success rate for measuring calcium release transients compared to 20% without surface engineering.
Synapse has enriched 10 related papers. Consider them for comparative context: