The loads developed in tubular-steel temporary props during the construction of the London Underground Jubilee Line Extension (JLE) station at Canada Water were measured using vibrating-wire strain gauges. Prop temperatures were monitored and their influence on the prop loads assessed. Wall movements were also measured, by means of inclinometers. In this paper, the temperature-normalized prop loads are compared with the results of modified limit equilibrium calculations. Prop loads and wall movements are compared with the results of a series of parametric finite-element analyses carried out using the program CRISP. On the basis of the finite-element analysis results, the design assumptions giving the closest correlation between measured and calculated prop loads and wall movements are identified.
No takes yet. Share an insight, caveat, or question.
Powrie et al. (2000) studied this question.